Magnetic inductive flowmeter. Max. Range (Water 20°C, 1 mPas), 163 m³/h. Installation length, 200mm.
Código Interno: PRO38752
Actualizado: 2020-05-08
EP magnetic inductive FlowmeterBrand: Kobold – Heinrichs (Alemania)
Model Sensor: EP-H-330B-1-SS-3-0
Model Transmitter: UMF2-G-1-1-F-0BK / E
Range (Water 20°C, 1 mPas), 163 m³/h. Installation length, 200mm. Connection, DN80 PN16 Form B1 DIN EN 1092-1. Output 1: 4 - 20mA
Paddle Type Flow Switch-PSR. Measuring range/paddle; 47.6-67.2 L/min paddle. Connection; G-thread.
Código Interno: PRO38640
Actualizado: 2020-05-08
Paddle Type Flow SwitchBrand: Kobold (Alemania)
Model: PSR-21-251-R-25-R-1
[PSR-21]:
Measuring range/paddle; 47.6-67.2 L/min paddle.
Connection; G-thread. Connection; 1\" (for PSR-xx25...).
Connecting cable; PVC-cable 1.5 m (standard)
Approvals: ATEX / IECEx.
Magnetic inductive flowmeter. Max. measuring range (Water 20°C, 1 mPas), 18 m³/h. Connection, 1″ Tri
Código Interno: PRO38629
Actualizado: 2020-05-08
EP magnetic inductive FlowmeterBrand: Heinrichs (Grupo Kobold) (Alemania)
Model Sensor:EP-P-7020-2-HH-1-0
Model Transmitter: UMF2-B-1-1-F-0BH
Max. range (Water 20°C, 1 mPas), 18 m³/h. Connection, 1\" Tri-Clover. Output 1: 4 - 20mA with HART-protocol. integrated transmitter.
Positive Displacement Flowmeter
Código Interno: PRO38603
Actualizado: 2020-05-08
Positive Displacement FlowmeterBrand: Kobold (USA)
Model: ZDM-4-1-40
Viscosities up to 100,000 cSt
Accuracy: ±0.3% of Flow
Fitting Orientation, Type, Side Ports, NPT
Max. Pressure:: 4500 PSIG ( 310 BAR)
Máx. Temp : -40...248 °F ( 120 °C)
Range Oil (GPM)** 0.2642...66.00
Flow Indicator with Flap. Nom. diameter, 150. Connection,ANSI-flange DN 150 / 6″. Housing, st.stmax
Código Interno: PRO38598
Actualizado: 2020-05-08
Flow Indicator with Flap DAK-2Brand: Kobold (Alemania)
Model: DAK-2-2-11H-A-1F-B
Nom. diameter, 150.
Connection,ANSI-flange DN 150 / 6\".
Housing, st.stmax. temp, 150 C. max. pressure, 16 bar.
Mounting position, Horizontal.
Flow direction, in direction of the arrow.
Magnetic inductive flowmeter. Max. Range (Water 20°C, 1 mPas), 40376 m³/h. Installation length, 1200
Código Interno: PRO38592
Actualizado: 2020-05-08
EP magnetic inductive flowmeterBrand: Kobold - Heinrichs (Alemania)
Model: EP-H-395B-1-SS-2-0 / UMF2-C-1-1-G-0BK/2
Max. Range (Water 20°C, 1 mPas), 40376 m³/h. Installation length, 1200 mm. Connection, 2½\" Class 150 RF ASME B16.5-2003. 1: 4 - 20mA with HART-protocol,
Magnetic inductive flowmeter. Max. measuring range (Water 20°C, 1 mPas), 670 m³/h. output 1: 4 – 20m
Código Interno: PRO38587
Actualizado: 2020-05-08
Magnetic inductive flowmeterBrand: Kobold (Heinrichs)
Model: EP-P-345B-1-SS-2-0/UMF2-C-1-1-G-0BK/2
Max. measuring range (Water 20°C, 1 mPas), 670 m³/h. output 1: 4 - 20mA with HART-protocol.
Connection, DN150 PN16. integrated transmitter. Temperature, -20°C...150°C.
Rotating Vane Flow Meter. Version, for pipe sizes 40-900 mm. electronic ZOD-Z1. Output, NPN OC + 1,
Código Interno: PRO38565
Actualizado: 2020-05-08
Rotating Vane Flow MeterModel: DOR-42-2-F-N8-F6-Z1-0
Brand: Kobold (Alemania)
DOR-42
Version, for pipe sizes 40-900 mm. electronic ZOD-Z1. Output, NPN OC + 1,5 V-pulse integral 1. Accuracy, ± 1 % FS. Max. temp 100 °C. Max. pressure 80 bar. Connection 1 1/2 NPT male.