Mostrando 1–12 de 120 resultados

Thermal Mass Flow Meter for Gas,Measuring range: 0.90-176 Nm³/h for tube DN 25 (1″)

Código: KMT-3-16-R-1-Z-L-1-N-Q-8
Valorado en 0 de 5

Código Interno: PRO44937

Thermal Mass Flow Meter for Gas
Brand: Kobold (Alemania)
Model: KMT-3-16-R-1-Z-L-1-N-Q-8

[KMT-3]
Function principle: Direct thermal flow
Sensor: remote
Flow direction: acc. Mounting
Power supply 18-30 VAC/DC
max. pressure / max. temperature PN 16 / 80 °C
Sensor material st. st./ plastic
[16] Measuring range: 0.90-176 Nm³/h for tube DN 25 (1\") 
[R] Connection: Ball valve with G-thread
[1] Display, LCD-display
[Z] Cable length sensor/electronic: 10 m with plug M12, 4-pins
[L] Medium, Air
[1] Units, SI units
[N] Physical size, output 1: Standard volume flow (standard Nm³/h)
[Q] Physical size, output 2: Consumption (standard Nm³)
[8] Consumption (standard Nm³): Analogue-output 4-20 mA / switch output

Medidor de flujo modular y compacto en línea (0.2-76.3 Nm³/h)

Código: KME-7-25-N-0-L-1-N-Q-4
Valorado en 0 de 5

Código Interno: PRO44761

Modular, compact Inline flow meter
Brand: Kobold (Alemania)
Model: KME-7-25-N-0-L-1-N-Q-4

[KMT-7]
Function principle, Direct thermal flow
Measuring tube, Aluminium
Sensor head/ sensor, st. steel 1.4404/ glass
Housing, Polycarbonet
Flow direction, +/- 3% of meas. value +0,3% full scale
Power supply, 18-30 VDC
Electr. connection, M12x1
max. pressure / max. temperature, PN 16 / -20…+60 °C
[25] Measuring range, 0.6-212 Nm³/h for tube DN 25 (1\")
[N] Connection, NPT- femal connection
[0] Display, without display
[L] Medium, air
[1] Units, SI units
[N] Physical size,output 1, Standard volume flow (standard Nm³/h)
[Q] Physical size,output 2, Consumption (standard Nm³)
[4] Output 1/ Output 2; Analogue-output 0-40 mA / totalizer output

Calorimetric Flowswitch, Compact Version

Código: KAL-K5-3-15-S-PG1
Valorado en 0 de 5

Código Interno: PRO35962

Calorimetric Flowswitch, Compact Version
Model: KAL-K5-3-15-S-PG1
Brand:  Kobold ( Alemania)

[KAL-K5]
Operating principle, calorimetric
Mounting position, all directions
Indication, DUO-LED and LED-chain
Max. Temperature, 80 °C (120 °C for KAL-KH)
Max. Pressure, 100 bar
Protection class, IP 65
Connection thread, NPT
[3]: Probe material, st.st. 1.4301
[15]: Connection, 1/2\"
[S]: Contact versión, N/O
[PG1]: Electron. connection/power supply, M 16x1,5 relay output 110 VAC

Calorimetric Flowswitch, Compact Version,max. temperature: 80 °C (120 °C for KAL-KH),Connection thre

Código: KAL-K5-3-15-S-PG0
Valorado en 0 de 5

Código Interno: PRO30300

MODEL:KAL-K5-3-15-S-PG0
[KAL-K5] Calorimetric Flowswitch, Compact Version
[3] Probe material: st.st. 1.4301
[15] Version: Standard; Connection: ½”
[S] Contact versión: N/O
[PG0] Electron. connection/power supply: M 16x1,5 relay output 230 VAC
Operating principle: calorimetric
Mounting position: all directions
Indication: DUO-LED and LED-chain
max. temperature: 80 °C (120 °C for KAL-KH)
max. pressure:100 bar
Protection class: IP 65
Connection thread: NPT

Ficha Técnica:
http://www.koboldmessring.com/fileadmin/koboldfiles/pdf/gb/s5gb_kal-k.pdf

Flujómetro de Masa-Térmica (0-50 cm³N/min)

Código: MAS-20-03-00-00-A
Valorado en 0 de 5

Código Interno: PRO4035

Mass-Flowmeter-Thermal MAS (Sin Display)
MODELO: MAS-20-03-00-00-A
MARCA: KOBOLD (ALEMANIA)

MAS-20:
Operating principle, thermal, Bypass
Mounting position, all directions
Indication, Sin display
Max. Temperature: 50°C
Max. Pressure: 10 bar
Design, Polyamide
03: Measuring range: 0-50 cm³N/min N2 (Equivale: 0-50 SCCM)
00: Connection, 1/4 NPT
00: Power supply, 12 VDC
A: Output, 4-20 mA

Mass-Flowmeter-Thermal, 1/4 NPT, 0-50 cm³N/min N2

Código: MAS-20-03-00-00-0
Valorado en 0 de 5

Código Interno: PRO4034

Mass-Flowmeter-Thermal MAS (Sin Display)
MODELO: MAS-20-03-00-00-0
MARCA: KOBOLD (ALEMANIA)
MAS-20:
Operating principle, thermal, Bypass
Mounting position, all directions
Indication, Sin display
Max. Temperature: 50°C
Max. Pressure: 10 bar
Design, Polyamide
03: Measuring range: 0-50 cm³N/min N2 (Equivale: 0-50 SCCM)
00: Connection, 1/4 NPT
00: Power supply, 12 VDC
0: Output, 0-5 V

Mass-Flowmeter-Thermal MAS

Código: MAS-10-03-00-00-A
Valorado en 0 de 5

Código Interno: PRO4033

Mass-Flowmeter-Thermal MAS
MODELO: MAS-10-03-00-00-A
MARCA: KOBOLD (ALEMANIA)
MAS-10:
Operating principle, thermal, Bypass
Mounting position, all directions
Indication, LC-Display
Max. Temperature: 50°C
Max. Pressure: 10 bar
Design, Polyamide
03: Measuring range: 0-50 cm³N/min N2 (Equivale: 0-50 SCCM)
00: Connection, 1/4 NPT
00: Power supply, 12 VDC
A: Output, 4-20 mA
Ficha Técnica:
http://www.koboldmessring.com/fileadmin/koboldfiles/pdf/gb/s5gb_mas-mfc.pdf

Mass-Flowmeter-Thermal MAS, Measuring range: 0-50 cm³N/min N2 (Equivale: 0-50 SCCM)

Código: MAS-10-03-00-00-0
Valorado en 0 de 5

Código Interno: PRO4032

Mass-Flowmeter-Thermal MAS
MODELO: MAS-10-03-00-00-0
MARCA: KOBOLD (ALEMANIA)
MAS-10:
Operating principle, thermal, Bypass
Mounting position, all directions
Indication, LC-Display
Max. Temperature: 50°C
Max. Pressure: 10 bar
Design, Polyamide
03: Measuring range: 0-50 cm³N/min N2 (Equivale: 0-50 SCCM)
00: Connection, 1/4 NPT
00: Power supply, 12 VDC
0: Output, 0-5 V
Ficha Técnica:
http://www.koboldmessring.com/fileadmin/koboldfiles/pdf/gb/s5gb_mas-mfc.pdf

Calorimetric Flow Monitor -for air,Connection, Compression fitting 1/2″ NPT,max. temperature 120 °C

Código: KAL-L-81N1WK-N4
Valorado en 0 de 5

Código Interno: PRO40257

Calorimetric Flow Monitor -for air-
Brands: Kobold 
Model: KAL-L-81 N1WK-N4
[KAL-L]:
Operating principle calorimetric
Mounting position all directions
Indication DUO-LED and LED-chain
Relais output SPDT
max. temperature 120 °C
max. pressure 8 bar
Protection class IP 65
[81 N1WK]: Connection, Compression fitting 1/2\" NPT
[N4]: Electron. connection/power supply, 1/2 NPT for screwed cable gland 24 VDC/AC

Calorimetric Flowswitch, Compact Version, 80 °C, 100 bar, M12x1 box 2 m cable, 5-pin

Código: KAL-K5-3-15-S-ST3+ZUB-KAB-12-K502
Valorado en 0 de 5

Código Interno: PRO43623

Calorimetric Flowswitch, Compact Version
Brand: Kobold-Alemania
Model: KAL-K5-3-15-S-ST3 + ZUB-KAB-12-K502

Operating principle: calorimetric
Mounting position: all directions
Indication: DUO-LED and LED-chain
max. Temperatura: 80 °C (120 °C for KAL-KH, KAL-43)
max. pressure: 100 bar
Protection class: IP 65
Connection thread: NPT
[3] Probe material: st.st. 1.4301
Version: Standard
[15] Connection: 1/2\"
[S] Contact versión: N/O
[ST3[ Electron. connection/power supply: plug connector M12x1 NPN/PNP 24 VDC
Accessories round plug
Brand: Kolbold- Alemania
Model: ZUB-KAB-12-K502
[K502] Version: M12x1 box 2 m cable, 5-pin

Modular, Flujómetro compacto en línea

Código: KME-7-50-N-1-L-1-N-Q-4
Valorado en 0 de 5

Código Interno: PRO46685

Modular, compact Inline flow meter
Brand: Kobold (Alemania)
Model: KME-7-50-N-1-L-1-N-Q-4

[KME-7]:
Function principle, Direct thermal flow
Measuring tube, Aluminium
Sensor head/ sensor, st. steel 1.4404/ glass
Housing, Polycarbonet
Flow direction, +/- 3% of meas. value +0,3% full scale
Power supply, 18-30 VDC
Electr. connection, M12x1
max. pressure / max. temperature, PN 16 / -20…+60 °C
[50]: Measuring range, 2.2-848.2 Nm³/h for tube DN 50 (2\")
[N]: Connection, NPT- femal connection
[1]: Display, LCD-display
[L]: Medium, air
[1]: Units, SI units
[N]: Physical size, output 1, Standard volume flow (standard Nm³/h)
[Q]: Physical size, output 2, Consumption (standard Nm³)
[4]: Output 1/ Output 2, Analogue-output 0-40 mA / totalizer output

Interruptor de flujo calorimétrico, versión compacta (3/4″ NPT)

Código: KAL-K5-4-20-S-PG0
Valorado en 0 de 5

Código Interno: PRO39884

Calorimetric Flowswitch, Compact Version
Model: KAL-K5-4-20-S-PG0
Brand: Kobold (Alemania)
[KAL-K5]:
Operating principle: calorimetric
Mounting position: all directions
Indication: DUO-LED and LED-chain
max. temperature: 80 °C 
max. pressure: 100 bar
Protection class: IP 65
Connection thread: NPT
Version: Standard
[4]: Probe material,  st.st. 1.4571 
Version, Standard
[20]: Connection, 3/4\"
[S]: Contact version, N/O
[PG0]: Electron. connection/power supply, M 16x1,5 relay output 230 VAC