Oval Gear Flow Meter/Counter. Range 10-150 L/min. Accuracy: ±0,2 % …1 % of reading. Electronic, Puls
Código Interno: PRO38064
Actualizado: 2020-05-08
DON-1-25H-N6-4-H0-N-0Oval Wheel Flowmeter Model DON
Range 10-150 L/min. Accuracy: ±0,2 % …1 % of reading. Electronic, Pulse output Hallsensor/Reed switch, Push Pull. Connection, 1\" NPT. Housing material: Aluminium. Max. temp: 120 °C. max. pressure 16…64 bar
Oval Gear Flow Meter/Counter. Range 50-580 L/min. Accuracy: ±0,2 % …1 % of reading. Mech. totaliser
Código Interno: PRO38043
Actualizado: 2020-05-08
Oval Wheel Flowmeter Model DONModel: DON-1-40H-F9-4-M4-0-0
Marca: Kobold (Alemania)
Range 50-580 L/min. Accuracy: ±0,2 % …1 % of reading.Mech. totaliser 4-digit
Connection, DIN flange DN 50, PN 16. Housing material: Aluminium. Max. temp: 80 °C. max. pressure 40 bar
Magnetic inductive flowmeter. Max. measuring range (Water 20°C, 1 mPas), 0.01-1 m3/h. output 1: 4 –
Código Interno: PRO38032
Actualizado: 2020-05-08
Magnetic inductive flowmeter.EP-P-006A-1-HH-1-1/UMF2-A-1-2-G-0BK
Max. measuring range (Water 20°C, 1 mPas), 0.01-1 m3/h. output 1: 4 - 20mA with HART-protocol.
Connection, 1/2\" Class 150 RF ASME B16.5-2003. integrated transmitter. Temperature, -20°C...150°C.
Magnetic inductive flowmeter. Max. Range (Water 20°C, 1 mPas), 1188 m³/h. Connection, 8″ Class 150 R
Código Interno: PRO38027
Actualizado: 2020-05-08
Magnetic inductive flowmeterEP-H-213R-1-HH-1-1/UMF2-A-1-2-G-0BK
Brand: Kobold-Heinrichs
Max. Range (Water 20°C, 1 mPas), 1188 m³/h. Connection, 8\" Class 150 RF. Output 1: 4 - 20mA with HART-protocol, pulse output: passive Um=24VDC. Material - lining, hard-rubber
Magnetic inductive flowmeter. Max. Range (Water 20°C, 1 mPas), 38 m³/h. Installation length 300 mm.
Código Interno: PRO38021
Actualizado: 2020-05-08
EP-H-205R-1-HH-1-1/UMF2-A-1-2-G-0BKMagnetic inductive flowmeter
Brand: Kobold-Heinrichs
Max. Range (Water 20°C, 1 mPas), 38 m³/h. Installation length 300 mm. Connection, 1½\" Class 150 RF. Output 1: 4 - 20mA with HART-protocol, pulse output: passive Um=24VDC.
Magnetic inductive flowmeter. Max. Range (Water 20°C, 1 mPas), 163 m³/h. Connection, ½» NPT (f). Out
Código Interno: PRO38000
Actualizado: 2020-05-08
Magnetic inductive flowmeterEP-H-330B-1-SS-1-0/UMF2-A-1-1-G-0BK
Brand: Kobold-Heinrichs
Max. Range (Water 20°C, 1 mPas), 163 m³/h. Connection, ½\" NPT (f). Output 1: 4 - 20mA with HART-protocol, pulse output: passive Um=24VDC. Material - lining, hard-rubber
Bypass-Level Indicators with glass tube. Installation length 800 mm. Connection flange ANSI 2″ 150 l
Código Interno: PRO37995
Actualizado: 2020-05-08
Bypass-Level Indicators with glass tubeMODEL: SZM-K-1-1-A9-S1-2 (800 mm)
BRAND: KOBOLD
Installation length 800 mm. Connection flange ANSI 2\" 150 lbs. 2 shut-off valves in connection. Protecting tube st. steel 1.440. Length of scale: 700 mm. Max. temp. 100 °C.
Rotating Vane-Low Volume-Dosing Electronic, Range:0.2 to 2.5 L/min.Connection: G 3/8. Output: pulse,
Código Interno: PRO37984
Actualizado: 2020-05-08
Rotating Vane-Low Volume-Dosing Electronic DFModelo: DF-25-E-R10-IHO-3K
Range:0.2 to 2.5 L/min.
Accurasy: 2.5 % f.s.
Connection: G 3/8.
Electrical connection: cable, 80 mm.
Output: pulse, NPN, max. 15 mA.
Power supply: 5 to 24 VDC.
Material: Stainless steel.
Magnetic inductive flowmeter. Max. Range (Water 20°C, 1 mPas), 2717 m³/h. Connection, 12″ Class 150.
Código Interno: PRO37957
Actualizado: 2020-05-08
Magnetic inductive flowmeterEP-H-215R-1-SS-2-0/UMF2-C-1-2-G-0BH-0
Brand: Kobold-Heinrichs
Max. Range (Water 20°C, 1 mPas), 2717 m³/h. Connection, 12\" Class 150. Output 1: 4 - 20mA with HART-protocol, pulse output: passive Um=24VDC. Material - lining, hard-rubber