Turbidity Sensor, 1” NPT
Código Interno: PRO42001
Turbidity Sensor
Model: AF16N
Brand: Optek
Model: AF16N
Brand: Optek
[AF16N]: Model
Description:
Single Channel NIR Absorption Sensor
Material: sensor body made of stainless steel SS 316 Ti, 1.4571 (standard)
Resolution: < ± 0.05 % of respective measuring range
Repeatability: < ± 0.5 % of respective measuring range (scattered light < ± 0.3 %)
Linearity: < ± 1 % of respective measuring range
Windows: 1-Pyrex, 2-Sapphire, 3-Sapphire Biotech
Protection: all optical parts have an IP rating of IP65 or higher
Process temperature permanent: 0 - 120 °C
Description:
Single Channel NIR Absorption Sensor
Material: sensor body made of stainless steel SS 316 Ti, 1.4571 (standard)
Resolution: < ± 0.05 % of respective measuring range
Repeatability: < ± 0.5 % of respective measuring range (scattered light < ± 0.3 %)
Linearity: < ± 1 % of respective measuring range
Windows: 1-Pyrex, 2-Sapphire, 3-Sapphire Biotech
Protection: all optical parts have an IP rating of IP65 or higher
Process temperature permanent: 0 - 120 °C
Technical Data:
Measurement principle, Channel absorption of light
Measurement wavelength, 730 nm - 970 nm
Detector, 1 silicon photodiode (hermetically sealed)
Process pressure, 10 mbar to 100 bar (0.15 psi to 1450 psi)
Calibrated Measuring Range, 0 – 1000 ppm
Light source, special incandescent tungsten lamp 5.0 V DC, 970 mA,
typical life span: 3 to 5 years (25,000 to 40,000 hours)
Process connection, Female Threads, 1” NPT
Including all required accessories, cables and assembling parts.
Measurement principle, Channel absorption of light
Measurement wavelength, 730 nm - 970 nm
Detector, 1 silicon photodiode (hermetically sealed)
Process pressure, 10 mbar to 100 bar (0.15 psi to 1450 psi)
Calibrated Measuring Range, 0 – 1000 ppm
Light source, special incandescent tungsten lamp 5.0 V DC, 970 mA,
typical life span: 3 to 5 years (25,000 to 40,000 hours)
Process connection, Female Threads, 1” NPT
Including all required accessories, cables and assembling parts.
Turbidity Sensor, 1” NPT
Código Interno: PRO42829
Turbidity Sensor
Model: AF16N
Brand: Optek
Model: AF16N
Brand: Optek
[AF16N]: Model
Description:
Single Channel NIR Absorption Sensor
Material: sensor body made of stainless steel SS 316 Ti, 1.4571 (standard)
Resolution: < ± 0.05 % of respective measuring range
Repeatability: < ± 0.5 % of respective measuring range (scattered light < ± 0.3 %)
Linearity: < ± 1 % of respective measuring range
Windows: 1-Pyrex, 2-Sapphire, 3-Sapphire Biotech
Protection: all optical parts have an IP rating of IP65 or higher
Process temperature permanent: 0 - 120 °C
Description:
Single Channel NIR Absorption Sensor
Material: sensor body made of stainless steel SS 316 Ti, 1.4571 (standard)
Resolution: < ± 0.05 % of respective measuring range
Repeatability: < ± 0.5 % of respective measuring range (scattered light < ± 0.3 %)
Linearity: < ± 1 % of respective measuring range
Windows: 1-Pyrex, 2-Sapphire, 3-Sapphire Biotech
Protection: all optical parts have an IP rating of IP65 or higher
Process temperature permanent: 0 - 120 °C
Technical Data:
Measurement principle, Channel absorption of light
Measurement wavelength, 730 nm - 970 nm
Detector, 1 silicon photodiode (hermetically sealed)
Process pressure, 10 mbar to 100 bar (0.15 psi to 1450 psi)
Calibrated Measuring Range, 0 – 1000 ppm
Light source, special incandescent tungsten lamp 5.0 V DC, 970 mA,
typical life span: 3 to 5 years (25,000 to 40,000 hours)
Process connection, Female Threads, 1” NPT
Including all required accessories, cables and assembling parts.
Measurement principle, Channel absorption of light
Measurement wavelength, 730 nm - 970 nm
Detector, 1 silicon photodiode (hermetically sealed)
Process pressure, 10 mbar to 100 bar (0.15 psi to 1450 psi)
Calibrated Measuring Range, 0 – 1000 ppm
Light source, special incandescent tungsten lamp 5.0 V DC, 970 mA,
typical life span: 3 to 5 years (25,000 to 40,000 hours)
Process connection, Female Threads, 1” NPT
Including all required accessories, cables and assembling parts.
Mounting Set
Código Interno: PRO42827
Mounting Set MS2 8M5 M24-M24 A-A F-O,O
Model: ERS-FR-SET-MS2
PN: 1102-0322-5050-02
Mounting set for sensor bodies 0120 (assembly &
hydrost.testing incl. if purchased with sensorbody)
2 window rings M24-8M5(1,4571)
16 socket head cap screws, M5x12 with lockwashers
Window material Sapphire.
Process Temp. -40 ... +300\' C
Process Press. 0-400 bar
*press.& temp.rating specified herein may subject
to limitations-see data sheets.
Window combination:
window1: Type 2A (O,Omm)
window2: Type 2A (O,Omm)
OPL = 40mm
Model: ERS-FR-SET-MS2
PN: 1102-0322-5050-02
Mounting set for sensor bodies 0120 (assembly &
hydrost.testing incl. if purchased with sensorbody)
2 window rings M24-8M5(1,4571)
16 socket head cap screws, M5x12 with lockwashers
Window material Sapphire.
Process Temp. -40 ... +300\' C
Process Press. 0-400 bar
*press.& temp.rating specified herein may subject
to limitations-see data sheets.
Window combination:
window1: Type 2A (O,Omm)
window2: Type 2A (O,Omm)
OPL = 40mm
Sensor Body ASME
Código Interno: PRO42826
Sensor Body ASME B1.20.1-NPT-1.00 0120S03F040
Model: ERS-FR-SENSOR-B1-20
PN: 0120-1104-03
Process connec.: Female thread ASME B1.20.1 NPT.
Material: St.steel SS 316 Ti (1,4571).
Line size: 1,00 inch., F-Value (mm): 40
Height (mm): 96, Surface(wetted): Ra<0,8um
Allowable temo TS: -40\'C/+120\'C.
Allowable press. PS: 10mbar-20 bar.
Model: ERS-FR-SENSOR-B1-20
PN: 0120-1104-03
Process connec.: Female thread ASME B1.20.1 NPT.
Material: St.steel SS 316 Ti (1,4571).
Line size: 1,00 inch., F-Value (mm): 40
Height (mm): 96, Surface(wetted): Ra<0,8um
Allowable temo TS: -40\'C/+120\'C.
Allowable press. PS: 10mbar-20 bar.
Photometric Analyzers
Código Interno: PRO42002
Photometric Analyzers[C4101]: Model
Brand: Optek(Alemania)
Description:
Series, C4000 Photometric Converter
Housing: 19\"-version for mounting in control cabinets 3 U / 42 HP
Protection: front IP40 / rear IP20 (mains supply secured against accidental touching)
Display: LCD graphic display black on white (240 x 128 pixel), LED background illuminated
System clock: accuracy approx. 1 minute/month (battery life approx. 15 years)
Data logger: 4 parallel measuring values, (ring buffer with approx. 25,000 data points x 4),
(interval: 1/second - 1/hour)
Technical Data:
Detector inputs (optek) (01 Unit)
Power supply 115/230, include
Relay-outputs, (03 Unit)
Failsafe-relay (active), include
Lamp output (optek), (01 Unit)
mA-outputs (0/4 - 20 mA), (02 Unit)
Including Panel Mounting Kit