Industrial Resistance Thermometers acc. DIN, max pressure 30 bar, 2 wire
Código Interno: PRO40314
Industrial Resistance Thermometers acc. DINBrand: Kobold (Alemania)
Model: MWD-L-6-G15-F-2-B-0-0
[MWD-L]:
Version, Protective tube acc. DIN 43772, filled with MgO, insert not removable
Protective tube material, st.st. 1.4404
Max. pressure (@ 20°C), 30 bar
Connection, fixed connection
Neckpipe, without
[6]: Diameter / length thermowell, 6 mm / 200 mm
[G15]: Process connection, G1/2 male
[F]: Sensor, 2x Pt100, cat. B, (-70..+400 °C)
[2]: Wiring, 2 wire
[B]: Terminal head, DIN B, screwd cover, aluminium
[0]: Head-mounted transmitter, without transmitter
[0]: Options, without
Industrial Resistance Thermometers acc. DIN (300mm)-MWD, 1/2 NPT
Código Interno: PRO40653
Industrial Resistance Thermometers acc. DINBrand: Kobold (Alemania)
Model: MWD-L-8-N15-C-4-E-0-0(300 mm)
[MWD-L]:
Version Protective tube acc. DIN 43772, filled with MgO, insert not removable
Protective tube material st.st. 1.4404
Max. pressure (@ 20°C) 30 bar
Connection fixed connection
Neck pipe without
[8]: Diameter / length thermowell, 8 mm / 300 mm
[N15]: Process connection, 1/2\" NPT male
[C]: Sensor, 1x Pt100, cat. A, (-70..+250 °C)
[4]: Wiring, 4 Wires
[E]: Terminal head, screw cap with chain, aluminium head with LCD display and HART transmitter include
[0]: Head-mounted transmitter, without transmitter
[0]: Options, without
Industrial Resistance Thermometers acc. DIN (160mm), 3 wires, 1/2 NPT male
Código Interno: PRO38797
Industrial Resistance Thermometers acc. DIN (160 mm)Brand: Kobold (Alemania)
Model: MWD-L-8-N15-C-3-G-B-0
[MWD-L]:
Version Protective tube acc. DIN 43772, filled with MgO, insert not removable
Protective tube material st.st. 1.4404
Max. pressure (@ 20°C) 30 bar
Connection fixed connection
Neck pipe without
[8]: Diameter / length thermowell, 8 mm / 160 mm
[N15]: Process connection, 1/2\" NPT male
[C]: Sensor, 1x Pt100, cat. A, (-70..+250 °C)
[3]: Wiring, 3 Wires
[G]: Terminal head, screw cap with chain, aluminium
[B]: Head-mounted transmitter, 2 wire transmitter with HART protocol model 5337D
[0]: Options, without
Screw-in Resistance Thermometers acc. to DIN Ex ia, G 1/2 AG, 2 wires
Código Interno: PRO41314
Screw-in Resistance Thermometers acc. to DIN Ex iaBrand: Kobold (Alemania)
Model: TWL-B94-10-2-3-2-G-0-0
[TWL-B94]:
Protective tube material: st. Steel 1.4571
Protective tube dimensions 8 x 6 mm
Form acc. DIN 43 772 2G
with stand-off yes
[10]: Immersion length, 100 mm
[2]: Connection, G 1/2 AG
[3]: Sensor type, 1x Pt100, cta. A (-80..+600 °C)
[2]: Wiring, 2 wires
[G]: Connection head, Form B with chain
[0]: Head transmitter, without
[0]: Option, without
Head Mounted Temperature Transmitters, Power supply 7,5..45 VDC
Código Interno: PRO41442
Head Mounted Temperature TransmittersBrand: Kobold (Alemania)
Model: KM-323-V
[KM-323]:
Input,
Pt100, Pt500, Pt1000,
Cu40, Cu100, Ni100, Ni550, Ni1000
Thermocouples:.B;E,J,K,N,R,S,T
Resistance: 100...400 Ohm, 10...2000 Ohm
Voltage:: 10..75 mV, 100...2000 mV
Output 4..20 mA
Mounting, connection head
Galvanic isolation: YES
Programmier Modus: U-Pro
Power supply 7,5..45 VDC
[V]: Factory setting: To be specified in words
Termómetros resistencia, 6 mm/ 145 mm, G1/2 male
Código Interno: PRO42482
Industrial Resistance Thermometers acc. DINBrand: Kobold (Alemania)
Model: MWD-F-6-G15-A-3-G-0-0
[MWD-F]:
Version, For mounting in thermowell, insert filled with MgO, removable
Protective tube material, st.st. 1.4404
Max. pressure (@ 20°C), Patm only with thermowell TWL-0
Connection, fixed connection
Neckpipe, without
[6]: Diameter / length thermowell, 6 mm / 145 mm
[G15]: Process connection, G1/2 male
[A]: Sensor, 1x Pt100, cat. B, (-70..+250 °C)
[3]: Wiring, 3 wires
[G]: Terminal head, screw cap with chain, aluminium
[0]: Head-mounted transmitter, without transmitter
[0]: Options, without
Termometro resistencia; 250C, 150mm
Código Interno: PRO41433
Industrial Resistance Thermometers acc. DINBrand: Kobold (Alemania)
Model: MWD-L-6-N15-C-3-G-0-0-150
[MWD-L]:
Version, Protective tube acc. DIN 43772, filled with MgO, insert not removable
Protective tube material, st.st. 1.4404
Max. pressure (@ 20°C), 30 bar
Connection, fixed connection
Neckpipe, without
[6]: Diameter / length thermowell, 6 mm / 150 mm
[N15]: Process connection, 1/2\" NPT male
[C]: Sensor, 1x Pt100, cat. A, (-70..+250 °C)
[3]: Wiring, 3 Wires
[G]: Terminal head, screw cap with chain, aluminium
[0]: Head-mounted transmitter, without transmitter
[0]: Options, without
Length thermowell, 150 mm
Termometro resistencia, 250C, 100mm, 1/4″ NPT
Código Interno: PRO40348
Industrial Resistance Thermometers acc. DINBrand: Kobold (Alemania)
Model: MWD-L-6-N8-D-3-E-0-0(100mm)+TMPZO-120 mm
[MWD-L]:
Version, Protective tube acc. DIN 43772, filled with MgO, insert not removable
Protective tube material, st.st. 1.4404
Max. pressure (@ 20°C), 30 bar
Connection, fixed connection
Neckpipe, without
[6]: Diameter / length thermowell, 6mm/100 mm
[N8]: Process connection, 1/4\" NPT male
[D]: Sensor, 2x Pt100, cat. A, (-70..+250 °C)
[3]: Wiring, 3 wires
[E]: Terminal head, Anschlusskopf
[0]: Head-mounted transmitter,without transmitter
[0]: Options, without
[TMPZO-120 mm]
Termopozo roscado recto
Uso: para sensor de temperatura
TMPZO-120 mm - conexión 1/2 npt
Termometro resistencia, 250C, 6mm, 1/2″ NPT
Código Interno: PRO39724
Industrial Resistance Thermometers acc. DINBrand: Kobold (Alemania)
Model: MWD-L-6-N15-C-3-G-0-0
[MWD-L]:
Version, Protective tube acc. DIN 43772, filled with MgO, insert not removable
Protective tube material, st.st. 1.4404
Max. pressure (@ 20°C), 30 bar
Connection, fixed connection
Neckpipe, without
[6]: Diameter / length thermowell, 6 mm
[N15]: Process connection, 1/2\" NPT male
[C]: Sensor, 1x Pt100, cat. A, (-70..+250 °C)
[3]: Wiring, 3 Wires
[G]: Terminal head, screw cap with chain, aluminium
[0]: Head-mounted transmitter, without transmitter
[0]: Options, without
Termometro resistencia, 250C, 6mm, 1/2″ NPT
Código Interno: PRO43332
Industrial Resistance Thermometers acc. DINBrand: Kobold (Alemania)
Model: MWD-L-6-N15-C-3-G-0-0
[MWD-L]:
Version, Protective tube acc. DIN 43772, filled with MgO, insert not removable
Protective tube material, st.st. 1.4404
Max. pressure (@ 20°C), 30 bar
Connection, fixed connection
Neckpipe, without
[6]: Diameter / length thermowell, 6 mm / 470 mm
[N15]: Process connection, 1/2\" NPT male
[C]: Sensor, 1x Pt100, cat. A, (-70..+250 °C)
[3]: Wiring, 3 Wires
[G]: Terminal head, screw cap with chain, aluminium
[0]: Head-mounted transmitter, without transmitter
[0]: Options, without
Industrial Resistance Thermometers acc. DIN, 6 mm / 130 mm, /2″ NPT male
Código Interno: PRO43333
Industrial Resistance Thermometers acc. DINBrand: Kobold (Alemania)
Model: MWD-L-6-N15-C-3-G-0-0(130mm)
[MWD-L]:
Version, Protective tube acc. DIN 43772, filled with MgO, insert not removable
Protective tube material, st.st. 1.4404
Max. pressure (@ 20°C), 30 bar
Connection, fixed connection
Neckpipe, without
[6]: Diameter / length thermowell, 6 mm / 130 mm
[N15]: Process connection, 1/2\" NPT male
[C]: Sensor, 1x Pt100, cat. A, (-70..+250 °C)
[3]: Wiring, 3 Wires
[G]: Terminal head, screw cap with chain, aluminium
[0]: Head-mounted transmitter, without transmitter
[0]: Options, without
Industrial Resistance Thermometers acc. DIN, (@ 20°C), 30 bar, 6 mm / 270 mm
Código Interno: PRO43335
Industrial Resistance Thermometers acc. DINBrand: Kobold (Alemania)
Model: MWD-L-6-N15-C-3-G-0-0 (270mm)
[MWD-L]:
Version, Protective tube acc. DIN 43772, filled with MgO, insert not removable
Protective tube material, st.st. 1.4404
Max. pressure (@ 20°C), 30 bar
Connection, fixed connection
Neckpipe, without
[6]: Diameter / length thermowell, 6 mm / 270 mm
[N15]: Process connection, 1/2\" NPT male
[C]: Sensor, 1x Pt100, cat. A, (-70..+250 °C)
[3]: Wiring, 3 Wires
[G]: Terminal head, screw cap with chain, aluminium
[0]: Head-mounted transmitter, without transmitter
[0]: Options, without