Turbidity Measurement System, 0-25….50 EBC
Código Interno: PRO43142
Turbidity Measurement SystemModel: ATS-K-B-E-N25
Model: Kobold (Alemania)
[ATS]:
Principle of measurement, scattered light tech.
Model, sensor
Material, st.st. 1.4571
Max. pressure, 16 bar
Process temperature, 0..100 (150) °C
Protection, IP65
Measuring Range, 0-25….50 EBC
[K]: Version, Turbidity sensor
[B]: Window, Borosilicate glass
[E]: Seal, EPDM
[N25]: Connection, 1\" NPT
Include:
Turbidity Measurement System
Brand: Kobold - Alemania
Model: ATT-K-S-E-P-1
[ATT]
Principle of measurement: 2 beam scattered light
Model: transducer
Analogue output 4-20 mA
Switching output 2 floating changeover contacts
Display 3-digit LED
Ambient temperature 0..50 °C
Protection IP40 (IP66 field housing)
[K]: Version,Transducer
[S]: Principle of measurement, 2 beam scattered light technique
[E]: Housing, Panel mounting
[P]: Unit, ppm
[1]: Power supply, 115 / 230 VAC
*Include Calibracion.
Sistema de medicion turbidez, 230 VAC
Código Interno: PRO37665
Turbidity Measurement SystemBrand: Kobold - Alemania
Model: ATT-K-S-E-P-1
[ATT]
Principle of measurement: 2 beam scattered light
Model: transducer
Analogue output 4-20 mA
Switching output 2 floating changeover contacts
Display 3-digit LED
Ambient temperature 0..50 °C
Protection IP40 (IP66 field housing)
[K]: Version,Transducer
[S]: Principle of measurement, 2 beam scattered light technique
[E]: Housing, Panel mounting
[P]: Unit, ppm
[1]: Power supply, 115 / 230 VAC
* Include calibracion
Turbidity Measurement System
Código Interno: PRO39910
Turbidity Measurement SystemModel: ATT-K-S-E-E-1
Brand: Kobold (Alemania)
[ATT]:
Principle of measurement absorption principle
Model transducer
Analogue output 4-20 mA
Switching output 2 floating changeover contacts
Display 3-digit LED
Ambient temperature 0..50 °C
Protection IP40 (IP66 field housing)
[K]: Versión, Transducer
[S]: Principle of measurement, 2 beam scattered light technique
[E]: Housing, Panel Mounting
[E]: Unit, EBC
[1]: Power supply, 115 / 230 VAC
Turbidity Measurement System, 0-25….50 EBC
Código Interno: PRO39906
Turbidity Measurement SystemModel: ATS-K-B-K-N25
Model: Kobold (Alemania)
[ATS]:
Principle of measurement, scattered light tech.
Model, sensor
Material, st.st. 1.4571
Max. pressure, 16 bar
Process temperature, 0..100 (150) °C
Protection, IP65
Measuring Range, 0-25….50 EBC
[K]: Version, Turbidity sensor
[B]: Window, Borosilicate glass
[K]: Seal, Kalrez
[N25]: Connection, 1\" NPT
Transmitter for Turbidity Meter, 4-20mA, 230 VAC, 5m cable
Código Interno: PRO39431
Turbidity Measurement SystemModel: ATT-K-S-E-E-1
Brand: Kobold (Alemania)
[ATT]:
Principle of measurement absorption principle
Model transducer
Analogue output 4-20 mA
Switching output 2 floating changeover contacts
Display 3-digit LED
Ambient temperature 0..50 °C
Protection IP40 (IP66 field housing)
[K]: Versión, Transducer
[S]: Principle of measurement, 2 beam scattered light technique
[E]: Housing, Panel Mounting
[E]: Unit, EBC
[1]: Power supply, 115 / 230 VAC
*********************************************************************************
Cable to Transducer
Model: ATK-KS-E05
Brand: Kobold (Alemania)
[ATK-K]: Model
[S]: principle of measurement , 2 beam scattered light
[E05]: Length of cable, 5 m cable
Turbidity Measurement System
Código Interno: PRO38813
Turbidity Measurement SystemBrand: Kobold (Alemania)
Model: ATT-K-A-F-C-1
[ATT]:
Principle of measurement absorption principle
Model transducer
Analogue output 4-20 mA
Switching output 2 floating changeover contacts
Display 3-digit LED
Ambient temperature 0..50 °C
Protection IP40 (IP66 field housing)
[K]: Versión, Transducer
[A]: Principle of measurement, Absorption principle
[F]: Housing, Field housing
[C]: Unit, CU
[1]: Power supply, 115 / 230 VAC
********************************************************
Datasheet: http://www.kobold.com/uploads/files/ats-k-gb-analysis.pdf
Turbidity Measurement System
Código Interno: PRO38446
Turbidity Measurement SystemBrand: Kobold (Alemania)
Model: ATL-F-E-A
[ATL]:
Principle of measurement absorption principle
Model sensor
Material st.st. 1.4571
Max. pressure 16 bar
Process temperature 0..100 °C
Protection IP 65
[F]: Wave length, 430 nm
[E]: Seal, EPDM (FDA)
[A]: Optical path length, 5 mm
**********************************************
Datasheet: http://www.kobold.com/uploads/files/l1gb_atl.pdf
Turbidity Measurement System, 4-20mA
Código Interno: PRO38445
Turbidity Measurement SystemBrand: Kobold (Alemania)
Model: ATT-K-A-E-C-1
[ATT]:
Principle of measurement absorption principle
Model transducer
Analogue output 4-20 mA
Switching output 2 floating changeover contacts
Display 3-digit LED
Ambient temperature 0..50 °C
Protection IP40 (IP66 field housing)
[K]: Versión, Transducer
[A]: Principle of measurement, Absorption principle
[E]: Housing, Panel Mounting
[C]: Unit, CU
[1]: Power supply, 115 / 230 VAC
********************************************************************************
Datasheet: http://www.kobold.com/uploads/files/ats-k-gb-analysis.pdf
Turbidity Meter ATS-K, 1″ NPT
Código Interno: PRO37664
Model: ATS-K-S-E-N25Turbidity Meter ATS-K
GENERAL DESCRIPTION:
Dual Light Scattering-method (11°)
Measuring range: 0...500 ppm
Connections: DIN-/ ANSI-flange, NPT, BSP thread, hygenic connection
Material: st. st.
Max. pressure: 16 bar
Max. temperature: 0...190°C
Measuring Accuracy: +/- 2% FS
Output: 4...20 mA, 2 limit switches
*********************************************
PRODUCTO DESCRIPTION:
Model: ATS-K-S-E-N25
K: Version, Turbidity sensor
S: Window, sapphire
E: Seal, EPDM
N25: Connection, 1\" NPT
Principle of measurement, scattered light tech.
Model, sensor
Material, st.st. 1.4571
Max. pressure, 16 bar
Process temperature, 0..100 (150) °C
Datasheet:
http://www.koboldmessring.com/fileadmin/koboldfiles/pdf/gb/a3gb_ats-k.pdf