Mostrando 1–12 de 3449 resultados

Interruptor del medidor de flujo de metal (0.1…1 L/min water)

Código: SMV-1201HF0R08Y
Valorado en 0 de 5

Código Interno: PRO47317

Metal-Flowmeter / Switch
Brand: Kobold (Alemania)
Model: SMV-12-01H-F0-R08-Y

[SMV-12]
Operating principle variable area
Mounting position vertical
Flow direction from bottom
Body material: St.St.
Seal: FPM
Side mounted indication: ----
Switch point, adjustable
Accuracy ±5 % FS
Max. temperature 100 °C*
Max. pressure 350 bar
[01H] Adjustment range: 0.1...1 L/min water
[F0] Contact ,1 ATEX-N/O 
[R08] Connection G 1/4 female
[Y] Set point preadjusted @ 0.5 l/min increas. flow.

Oval Gear Flowmeter

Código: OVZ-30-3-G5-N-I303+ZUB-KAB-12K502
Valorado en 0 de 5

Código Interno: PRO47310

Oval Gear Flowmeter
Brand: Kobold (Alemania)
Model: OVZ-30-3–G5-N-I303

[OVZ-30]
Operating principle Oval Gear
Mounting position horizontal / vertical
Measuring range by 10-100 mm²/s, 1,6-40 L/min
Max. temperature 80 °C
Accuracy +-2,5% FS
Protection IP 65
[3]: Body material / cover / max. pressure, Aluminium / PMMA / PN 16
[G5]: Connection, G 3/4 
[N]: Seals, NBR
[I303]: Electronic, Hall sensor / round plug M12x1 

Include:
Accessories round plug
Brand: Kobold (Alemania)
Model: ZUB-KAB-12K502
[12K502]: Version, M12x1 box 2 m cable, 5-pin

Flujómetro de bajo volumen (2.5…25 L/h water; 1/4 NPT)

Código: KDF-22-28-N-V-0-00-0
Valorado en 0 de 5

Código Interno: PRO34070

Low Volume Flowmeter
Brand: Kobold (Alemania)
Model: KDF-22-28-N-V-0-00-0

[KDF-22]:
Mounting length, 125 mm
Operating principle, variable area
Flow direction, from bottom to top
Body material, st.st.
Glass, Borosilicate
Accuracy, class 2.5
Max. temperature without/with contact, 100 °C / 80 °C
Max. pressure, PN 16
[28]: Measuring range, 2.5...25 L/h water
[N]: Connection, 1/4 NPT
[V]: Seal, FPM
[0]: Panel mounting kit, w/o
[00]: Contacts measuring range, w/o
[0]: Flow differential pressure regulator, w/o

Heavy Duty Differential Pressure Flowmeters

Código: KEL-D-5-1-A-40
Valorado en 0 de 5

Código Interno: PRO47303

Heavy Duty Differential Pressure Flowmeters
Brand: Kobold (USA)
Model: KEL-D-5-1-A-40

[KEL-D]:
Back-lit Digital Rate/ Total Bargraph Display with 4-20 mA Output.
Flow Range; 4 a 20 GPM
Maximum Pressure: 230 PSIG or ANSI Cl B16.5
Enclosure: IP65 (NEMA 4)
Power Supply:18 ... 30 VDC
Analog Output:4-20 mA, 500 ohm max
Switch Output: 2x Relay, 50 VDC/VAC max
[5]: Turndown; 5:1
[1]: Body Material;  Brass or Brass/ Cast Iron
[A]: Fitting Style; ANSI
[40]: Piping Size;  1-1/2\"

Heavy Duty Differential Pressure Flowmeters

Código: KEL-D-5-1-N-40
Valorado en 0 de 5

Código Interno: PRO47302

Heavy Duty Differential Pressure Flowmeters
Brand: Kobold (USA)
Model: KEL-D-5-1-N-40

[KEL-D]:
Back-lit Digital Rate/ Total Bargraph Display with 4-20 mA Output.
Flow Range; 4 a 20 GPM
Maximum Pressure: 230 PSIG or ANSI Cl B16.5
Enclosure: IP65 (NEMA 4)
Power Supply:18 ... 30 VDC
Analog Output:4-20 mA, 500 ohm max
Switch Output: 2x Relay, 50 VDC/VAC max
[5]: Turndown; 5:1
[1]: Body Material;  Brass or Brass/ Cast Iron
[N]: Fitting Style; NPT
[40]: Piping Size;  1-1/2\"

Heavy Duty Differential Pressure Flowmeters, 1 NPT, 4 A 20 mA

Código: KEL-D-5-2-N-25
Valorado en 0 de 5

Código Interno: PRO39738

Heavy Duty Differential Pressure Flowmeters
Brand: Kobold (USA)
Model: KEL-D-5-2-N-25

[KEL-D]:
Back-lit Digital Rate/ Total Bargraph Display with 4-20 mA Output.
Flow Range; 4 a 20 GPM
Maximum Pressure: 230 PSIG or ANSI Cl B16.5
Enclosure: IP65 (NEMA 4)
Power Supply:18 ... 30 VDC
Analog Output:4-20 mA, 500 ohm max
Switch Output: 2x Relay, 50 VDC/VAC max
[5]: Turndown; 5:1
[2]: Body Material; Stainless Steel
[N]: Fitting Style; NPT
[25]: Piping Size; 1\"

Variable Area Flowmeter, 100 L/h , G 1/2

Código: URM-55-24H-I4-0
Valorado en 0 de 5

Código Interno: PRO38792

Variable Area Flowmeter/-switch Glass Cone with Thread Connection
Brand: Kobold (Alemania)
Model: URM-55-24H-I4-0
[URM-55]
Mounting position: vertical, flow direction from bottom
Accuracy: Class 4
Max. temperature: 100°C
Max. pressure: 6 bar...16 bar depend see data sheet
Material: connection, float / seal/ ring, 1.4404 / FPM / PTFE
[24H]: Range Full Scale* water, 100 L/h 
[I4]: Connection female: G 1/2
[0]: Contacts: w/o, for meas. range: all

All-Metal Variable Area Flowmeter BGN, DN80, 3.9 a 39 m3/h

Código: BGN-P80-330B-V-0-0-L-B-S-5-0-0-H
Valorado en 0 de 5

Código Interno: PRO39530

All-Metal Variable Area Flowmeter BGN
BGN-P80-330B-V-0-0-L-B-S-5-0-0-H
Marca: Kobold-Heinrichs
[BGN-P80]:
Model, Stainless Steel, Wetted Parts PTFE, process temperature ? 125°C, process pressure max. 16 bar
[330B]: Connection, size, DN80 PN16 Form B1 DIN EN 1092-1 (old DIN-standard on request)
[V]: Range (water 20°C, 1 mPas), agua de mar 3.9 a 39 m3/h
[0]: Heating / cooling, without heating / Cooling
[0]: Damping / spring stop, without
[L]: Self draining, with self draining body
[B]: Certificates, Inspection certificate 3.1 with material certificate (DIN EN 10204:2004)
[S]: Display,
      Standard display housing,
      Process temperature ? 150°C for electrical output,
      Process temperature ? 200°C for local indication
[5]: Scale, Measuring range-Scale (Media)
[0]: Switches, without
      Ambient temperature, -40° to +80°C
[0]: Accessories, without
[H]: Design,Heinrichs

Interruptor del flujómetro de área variable-DSV (2-18 l/min water, 1/2 NPT female)

Código: DSV-11-05H-00-N15
Valorado en 0 de 5

Código Interno: PRO45579

Variable Area Flowmeter/-switch
Model: DSV-11-05H-00-N15
Brand: Kobold (Alemania)

[DSV-11]
Operating principle: variable area
Mounting position: vertical
Flow direction: from bottom
Fitting material: Brass
Sight glass: Borosilicate
Accuracy: ±4 % FS
Max. temperature: 100 °C (metal-float)
Max. pressure: 10 bar
[05H] Measuring range :2...18 L/min water
[00] Contact w/o
[N15] Connection measuring range: 1/2 NPT female (up to 18 L/min)

Low Volume Flowmeter

Código: KDG-92-88-N-V-0-00-0
Valorado en 0 de 5

Código Interno: PRO45888

Low Volume Flowmeter
Brand: Kobold (Alemania)
Model: KDG-92-88-N-V-0-00-0

[KDG-92]
Mounting length 90 mm
Operating principle variable area
Flow direction from bottom to top
Body material st.st.
Glass Borosilicate
Accuracy class 3
Max. temperature without/with contact 100 °C / 70 °C
Max. pressure PN 16
With needle valve
[88] 2,0...20 L/h air
[N] Connection, 1/4 NPT
[V] Seal, FPM
[0] Panel mounting kit, w/o
[00] Contacts measuring range, w/o
[0] Flow differential pressure regulator, w/o

 

Compact Magnetic Inductive Flow Meter

Código: MIK-6FC-55-K-S300
Valorado en 0 de 5

Código Interno: PRO45868

Compact Magnetic Inductive Flow Meter
Brand: Kobold (Alemania)
Model: MIK-6FC-55-K-S300 

[MIK-6FC]:
Operating principle: Magnetic Inductive
Mounting position: all directions
Max. temperature/pressure: 80 °C / 10 bar
Protection: IP 65
Housing: PVDF
Electrodes: Hastelloy
Seal: FFKM
[55]: Measuring range, 5...100 L/min G 1½ male 
[K]: Connection set, PVC-glue connection: G 1½ - Ø26/32 mm
[S300]: Evaluation electronic for MIK, 24 VDC, plug M12, Relay 

Full-Metal Variable Area Flowmeter, Ammonia Gas. Measuring range, 13-133 Nm3/h. Max. temperature 350

Código: BGN-S-10305BD-0-0-0-0-S-2-2-0K
Valorado en 0 de 5

Código Interno: PRO45863

Full Metal Variable Area Flow Meter and Counter
Brand: Kobold (Alemania)
Model: BGN-S-10305BD-0-0-0-0-S-2-2-0K

[BGN-S]
Operating principle variable area
Mounting position vertical
Flow direction from bottom to the top
Material tube st. st.
casing -
Accuracy 1,6% F.S
Max. temperature 350 °C
Max. pressure PN 40
[10305BD]: Measuring range, 2,5-25 L/h
Nominal diameter DIN EN 1092-1 , DIN DN 15
[0]: Heating / Cooling, without
[0]: Damping/spring stop, without
[0]: Draining body, without
[0]: Certificates (NET prices, no discount), without certificate
[S]: Display, Aluminium
[2]: Display, Water measuring range
[2]: Electrical output, 2 inductive switches: SIL
[0K]: Accessories, without